{"id":85503,"date":"2021-06-03T15:58:41","date_gmt":"2021-06-03T13:58:41","guid":{"rendered":"https:\/\/www.mwm.net\/?page_id=85503"},"modified":"2021-06-14T12:50:35","modified_gmt":"2021-06-14T10:50:35","slug":"gas-engine-tcg-2016","status":"publish","type":"page","link":"https:\/\/www.mwm.net\/en\/gas-engines-gensets\/gas-engine-tcg-2016\/","title":{"rendered":"Gas Engine TCG 2016"},"content":{"rendered":"<h2 class=\"subheadline noborder\">MWM TCG 2016 V08, V12, V16 Gas Engine \u2013 Efficiency across the board!<\/h2>\n<h3>Compelling arguments \u2013 Features at a glance.<\/h3>\n<div class=\"spcl_blts\">\n<ul>\n<li>Output range from 400 to 800 kW<sub>el<\/sub><\/li>\n<li>High Flexibility<\/li>\n<li>Runs on all gas types: natural gas, biogas, landfill gas, sewage gas, mine gas, etc.<\/li>\n<li>Mainly used for biogas plants and small CHP plants in Europe<\/li>\n<li>Highest electrical efficiency in the output range up to 1,000 kW<sub>el<\/sub><\/li>\n<li>More than 1900 power generators with approximately 1,000,000 kW<sub>el<\/sub> already installed around the globe<\/li>\n<li>Low installation and operating costs<\/li>\n<\/ul>\n<\/div>\n<div class=\"pro_grphc\">\n<div class=\"cntct_rght\"><a href=\"https:\/\/www.mwm.net\/en\/contact\/contact-sales\/\">Contact Sales <strong>Click here<\/strong><\/a><\/div>\n<\/div>\n<div class=\"blu_sec\">\n<h4>Auf dieser Seite<\/h4>\n<p><a href=\"#gasmotor_TCG_2016_beschreibung\">Description \u2013 MWM Gas Engine TCG 2016<\/a><br \/>\n<a href=\"#gasmotor_TCG_2016_investitionskosten\">Lower Investment Costs &#8211; MWM Gas Engine TCG 2016<\/a><br \/>\n<a href=\"#gasmotor_TCG_2016_flexibilitaet\">High Flexibility &#8211; MWM Gas Engine TCG 2016<\/a><br \/>\n<a href=\"#gasmotor_TCG_2016_leistungsdaten\">Performance Data &#8211; MWM Gas Engine TCG 2016<\/a><br \/>\n<a href=\"#gasmotor_TCG_2016_serviceintervalle\">Specifications and Service Intervals &#8211; MWM Gas Engine TCG 2016<\/a>\n<\/div>\n<div class=\"patch-content\">\n<p>The MWM gas engines of the TCG 2016 series are perfectly geared to the challenges of a dynamic market environment. Our models in the output range of 400 \u2013 800 kW<sub>el<\/sub> meet the high requirements of a broad range of applications and guarantee efficiency, reliability, flexibility and environmental sustainability, together with low lifecycle costs and high profitability.<\/p>\n<\/div>\n<div class=\"patch-content\">\n<h2 class=\"subheadline\"><a name=\"gasmotor_TCG_2016_beschreibung\"><\/a>Description \u2013 MWM Gas Engine TCG 2016<\/h2>\n<h3>Consumes up to 15 Percent Less Gas than Comparable Gensets Thanks to Its Best-of-Class Efficiency<\/h3>\n<ul>\n<li>Special piston variants with different compression for biogas and natural gas operation<\/li>\n<li>Optimized gas exchange and camshaft, spark plugs with integrated pre-combustion chamber<\/li>\n<li>Even load balancing over the individual cylinders enables higher load level and maximum utilization of the engine reserves in terms of output and efficiency<\/li>\n<li>New closed crankcase ventilation optimizes combustion and increases efficiency by utilizing the blow-by gas<\/li>\n<li>Consistent downsizing of dead spaces improves complete combustion of the gas mixture, resulting in reduced fuel consumption and HC- and CO-emissions and higher efficiency<\/li>\n<\/ul>\n<h3>Long Service Intervals<\/h3>\n<ul>\n<li>Longest time interval until major overhaul compared to competitors<\/li>\n<li>Use of Xchange components enables time savings of up to 75 percent during the major overhaul, resulting in reduced costs<\/li>\n<li>Turbocharger for TCG 2016C series, depending on application with water-cooled bearing housing, thus reducing maintenance costs for turbocharger<\/li>\n<li>No contamination of the turbocharger compressor thanks to improved separation of gas and liquid phase, resulting in long maintenance intervals<\/li>\n<\/ul>\n<h3>Very Low Lubricant Consumption<\/h3>\n<ul>\n<li>With its lubricant consumption of only 0.1 &#8211; 0.2 g\/kWh, TCG 2016C sets competitive standards<\/li>\n<li>Lubricant savings of up to 50 percent compared to competitors<\/li>\n<\/ul>\n<\/div>\n<div class=\"patch-content\">\n<h2 class=\"subheadline\"><a name=\"gasmotor_TCG_2016_investitionskosten\"><\/a>Lower Investment Costs &#8211; MWM Gas Engine TCG 2016<\/h2>\n<h3>Niedrige Installationskosten dank kleiner Abmessungen<\/h3>\n<h3>Low Installation Costs Thanks to Smaller Dimensions<\/h3>\n<ul>\n<li>Compact genset design saves investment costs through smaller engine space and fewer plant peripherals<\/li>\n<li>Setup space up to 50 percent smaller than for comparable gensets<\/li>\n<\/ul>\n<\/div>\n<div class=\"patch-content\">\n<h2 class=\"subheadline\"><a name=\"gasmotor_TCG_2016_flexibilitaet\"><\/a>High Flexibility &#8211; MWM Gas Engine TCG 2016<\/h2>\n<h3>TEM Control Enables Use of Diverse Gas Types<\/h3>\n<ul>\n<li>Same electrical output with natural gas and biogas<\/li>\n<li>Further information on the TEM control<\/li>\n<\/ul>\n<\/div>\n<div class=\"patch-content tbl_cntnt\">\n<h2 class=\"subheadline\"><a name=\"gasmotor_TCG_2016_leistungsdaten\"><\/a>Performance Data &#8211; MWM Gas Engine TCG 2016<\/h2>\n<h3>Natural gas applications, NO<sub>x<\/sub> &le; 500 mg\/Nm<sup>3<\/sup> *<\/h3>\n<table cellpadding=\"0\" cellspacing=\"0\" width=\"100%\">\n<thead>\n<tr>\n<th colspan=\"2\" class=\"border\"><\/th>\n<th colspan=\"2\" class=\"border\">TCG 2016 V08 C<\/th>\n<th colspan=\"2\" class=\"border\">TCG 2016 V12 C<\/th>\n<th colspan=\"2\">TCG 2016 V16 C<\/th>\n<\/tr>\n<tr>\n<th colspan=\"2\" rowspan=\"1\" class=\"border\">Engine type<\/th>\n<th>50 Hz<\/th>\n<th class=\"border\">60 Hz<\/th>\n<th>50 Hz<\/th>\n<th class=\"border\">60 Hz<\/th>\n<th>50 Hz<\/th>\n<th>60 Hz<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"odd\">\n<td>Electrical output<\/td>\n<td class=\"border\">kW<\/td>\n<td class=\"border\">400<\/td>\n<td class=\"border\">400<\/td>\n<td class=\"border\">600<\/td>\n<td class=\"border\">600<\/td>\n<td class=\"border\">800<\/td>\n<td>800<\/td>\n<\/tr>\n<tr class=\"even\">\n<td>Thermal output \u00b1 8%<\/td>\n<td class=\"border\">kW<\/td>\n<td class=\"border\">427<\/td>\n<td class=\"border\">445<\/td>\n<td class=\"border\">654<\/td>\n<td class=\"border\">675<\/td>\n<td class=\"border\">854<\/td>\n<td>886<\/td>\n<\/tr>\n<tr class=\"odd\">\n<td>Electrical efficiency <\/td>\n<td class=\"border\">%<\/td>\n<td class=\"border\">42.3<\/td>\n<td class=\"border\">41.4<\/td>\n<td class=\"border\">42.0<\/td>\n<td class=\"border\">41.3<\/td>\n<td class=\"border\">42.5<\/td>\n<td>41.6<\/td>\n<\/tr>\n<tr class=\"even\">\n<td>Thermal efficiency<\/td>\n<td class=\"border\">%<\/td>\n<td class=\"border\">45.2<\/td>\n<td class=\"border\">46.0<\/td>\n<td class=\"border\">45.8<\/td>\n<td class=\"border\">46.5<\/td>\n<td class=\"border\">45.3<\/td>\n<td rowspan=\"1\">46.3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table cellpadding=\"0\" cellspacing=\"0\" width=\"100%\">\n<thead>\n<tr>\n<th colspan=\"2\" class=\"border\"><\/th>\n<th>TCG 2016 V12 C_515<\/th>\n<\/tr>\n<tr>\n<th colspan=\"2\" rowspan=\"1\" class=\"border\">Engine type<\/th>\n<th>50 Hz<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"odd\">\n<td>Electrical output<\/td>\n<td class=\"border\">kW<\/td>\n<td>515<\/td>\n<\/tr>\n<tr class=\"even\">\n<td>Thermal output \u00b1 8%<\/td>\n<td class=\"border\">kW<\/td>\n<td>513<\/td>\n<\/tr>\n<tr class=\"odd\">\n<td>Electrical efficiency<\/td>\n<td class=\"border\">%<\/td>\n<td>43.2<\/td>\n<\/tr>\n<tr class=\"even\">\n<td>Thermal efficiency<\/td>\n<td class=\"border\">%<\/td>\n<td>43.1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h3>Biogas, landfill gas, and sewage gas applications, NO<sub>x<\/sub> &le; 500 mg\/Nm<sup>3<\/sup> *<\/h3>\n<table cellpadding=\"0\" cellspacing=\"0\" width=\"100%\">\n<thead>\n<tr>\n<th colspan=\"2\" class=\"border\"><\/th>\n<th colspan=\"2\" class=\"border\">TCG 2016 V08 C<\/th>\n<th colspan=\"2\" class=\"border\">TCG 2016 V12 C<\/th>\n<th colspan=\"2\">TCG 2016 V16 C<\/th>\n<\/tr>\n<tr>\n<th colspan=\"2\" rowspan=\"1\" class=\"border\">Engine type<\/th>\n<th>50 Hz<\/th>\n<th class=\"border\">60 Hz<\/th>\n<th>50 Hz<\/th>\n<th class=\"border\">60 Hz<\/th>\n<th>50 Hz<\/th>\n<th>60 Hz<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"odd\">\n<td>Electrical output<\/td>\n<td class=\"border\">kW<\/td>\n<td class=\"border\">400<\/td>\n<td class=\"border\">400<\/td>\n<td class=\"border\">600<\/td>\n<td class=\"border\">600<\/td>\n<td class=\"border\">800<\/td>\n<td>800<\/td>\n<\/tr>\n<tr class=\"even\">\n<td>Thermal output \u00b1 8%<\/td>\n<td class=\"border\">kW<\/td>\n<td class=\"border\">393<\/td>\n<td class=\"border\">415<\/td>\n<td class=\"border\">593<\/td>\n<td class=\"border\">632<\/td>\n<td class=\"border\">788<\/td>\n<td>827<\/td>\n<\/tr>\n<tr class=\"odd\">\n<td>Electrical efficiency <\/td>\n<td class=\"border\">%<\/td>\n<td class=\"border\">42.8<\/td>\n<td class=\"border\">41.6<\/td>\n<td class=\"border\">42.7<\/td>\n<td class=\"border\">41.4<\/td>\n<td class=\"border\">42.8<\/td>\n<td>41.7<\/td>\n<\/tr>\n<tr class=\"even\">\n<td>Thermal efficiency<\/td>\n<td class=\"border\">%<\/td>\n<td class=\"border\">42.0<\/td>\n<td class=\"border\">43.1<\/td>\n<td class=\"border\">42.2<\/td>\n<td class=\"border\">43.6<\/td>\n<td class=\"border\">42.2<\/td>\n<td rowspan=\"1\">43.2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>* 5% O<sub>2<\/sub> and dry exhaust gases<\/p>\n<\/div>\n<div class=\"patch-content tbl_cntnt\">\n<h2 class=\"subheadline\"><a name=\"gasmotor_TCG_2016_serviceintervalle\"><\/a>Specifications and Service Intervals &#8211; MWM Gas Engine TCG 2016<\/h2>\n<h3>Dimensions and Weights<\/h3>\n<table cellpadding=\"0\" cellspacing=\"0\" width=\"100%\">\n<thead>\n<tr>\n<th colspan=\"2\" class=\"border\"><\/th>\n<th colspan=\"2\" class=\"border\">TCG 2016 V08 C<\/th>\n<th colspan=\"2\" class=\"border\">TCG 2016 V12 C<\/th>\n<th colspan=\"2\">TCG 2016 V16 C<\/th>\n<\/tr>\n<tr>\n<th colspan=\"2\" rowspan=\"1\" class=\"border\">Engine type<\/th>\n<th>50 Hz<\/th>\n<th class=\"border\">60 Hz<\/th>\n<th>50 Hz<\/th>\n<th class=\"border\">60 Hz<\/th>\n<th>50 Hz<\/th>\n<th>60 Hz<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"odd\">\n<td>Length<\/td>\n<td class=\"border\">mm<\/td>\n<td class=\"border\">3090<\/td>\n<td class=\"border\">3170<\/td>\n<td class=\"border\">3690<\/td>\n<td class=\"border\">3770<\/td>\n<td class=\"border\">4090<\/td>\n<td>4130<\/td>\n<\/tr>\n<tr class=\"even\">\n<td>Width<\/td>\n<td class=\"border\">mm<\/td>\n<td class=\"border\">1490<\/td>\n<td class=\"border\">1490<\/td>\n<td class=\"border\">1490<\/td>\n<td class=\"border\">1490<\/td>\n<td class=\"border\">1590<\/td>\n<td>1490<\/td>\n<\/tr>\n<tr class=\"odd\">\n<td>Height<\/td>\n<td class=\"border\">mm<\/td>\n<td class=\"border\">2190<\/td>\n<td class=\"border\">2190<\/td>\n<td class=\"border\">2190<\/td>\n<td class=\"border\">2190<\/td>\n<td class=\"border\">2190<\/td>\n<td>2190<\/td>\n<\/tr>\n<tr class=\"even\">\n<td>Dry weight genset<\/td>\n<td class=\"border\">kg<\/td>\n<td class=\"border\">5340<\/td>\n<td class=\"border\">5120<\/td>\n<td class=\"border\">7000<\/td>\n<td class=\"border\">6260<\/td>\n<td class=\"border\">8450<\/td>\n<td rowspan=\"1\">6780<\/td>\n<\/tr>\n<tr class=\"odd\">\n<td>Bore \/ stroke<\/td>\n<td class=\"border\">mm<\/td>\n<td class=\"border\">132\/160<\/td>\n<td class=\"border\">132\/160<\/td>\n<td class=\"border\">132\/160<\/td>\n<td class=\"border\">132\/160<\/td>\n<td class=\"border\">132\/160<\/td>\n<td>132\/160<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h3>Service Intervals<\/h3>\n<table cellpadding=\"0\" cellspacing=\"0\" width=\"100%\">\n<colgroup>\n<col width=\"35%\" \/>\n<col width=\"25%\" \/>\n<col width=\"20%\" \/>\n<col width=\"20%\" \/>\n    <\/colgroup>\n<thead>\n<tr>\n<th class=\"border\">&nbsp;<\/th>\n<th class=\"border\">First service (check valve clearance)<\/th>\n<th class=\"border\">Cylinder head inspection<\/th>\n<th>Major overhaul<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"odd\">\n<td class=\"border\">Natural gas and purified biogas, landfill gas, and sewage gas<\/td>\n<td class=\"border\">2000 oh<\/td>\n<td class=\"border\">32000 oh*<\/td>\n<td>64000 oh<\/td>\n<\/tr>\n<tr class=\"even\">\n<td class=\"border\">Unpurified biogas, landfill gas, and sewage gas<\/td>\n<td class=\"border\">1500 oh<\/td>\n<td class=\"border\">12000 oh*<\/td>\n<td>48000 oh<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>* &#8220;at the latest&#8221;\n<\/p><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Suitable for all gas types. Mainly used for biogas plants and small CHP plants.<\/p>\n","protected":false},"author":6,"featured_media":85505,"parent":1062,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"product-template.php","meta":{"_acf_changed":false,"footnotes":""},"tags":[188],"class_list":["post-85503","page","type-page","status-publish","has-post-thumbnail","hentry","tag-gas-engines"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v27.2) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Gas Engine TCG 2016<\/title>\n<meta name=\"description\" content=\"Suitable for all gas types. Mainly used for biogas plants and small CHP plants.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.mwm.net\/en\/gas-engines-gensets\/gas-engine-tcg-2016\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Gas Engine TCG 2016\" \/>\n<meta property=\"og:description\" content=\"Suitable for all gas types. Mainly used for biogas plants and small CHP plants.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.mwm.net\/en\/gas-engines-gensets\/gas-engine-tcg-2016\/\" \/>\n<meta property=\"og:site_name\" content=\"MWM\" \/>\n<meta property=\"article:modified_time\" content=\"2021-06-14T10:50:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.mwm.net\/wp-content\/uploads\/2021\/05\/TCG-2016.png\" \/>\n\t<meta property=\"og:image:width\" content=\"630\" \/>\n\t<meta property=\"og:image:height\" content=\"551\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.mwm.net\/en\/gas-engines-gensets\/gas-engine-tcg-2016\/\",\"url\":\"https:\/\/www.mwm.net\/en\/gas-engines-gensets\/gas-engine-tcg-2016\/\",\"name\":\"Gas Engine TCG 2016\",\"isPartOf\":{\"@id\":\"https:\/\/www.mwm.net\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.mwm.net\/en\/gas-engines-gensets\/gas-engine-tcg-2016\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.mwm.net\/en\/gas-engines-gensets\/gas-engine-tcg-2016\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.mwm.net\/wp-content\/uploads\/2021\/05\/TCG-2016.png\",\"datePublished\":\"2021-06-03T13:58:41+00:00\",\"dateModified\":\"2021-06-14T10:50:35+00:00\",\"description\":\"Suitable for all gas types. Mainly used for biogas plants and small CHP plants.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.mwm.net\/en\/gas-engines-gensets\/gas-engine-tcg-2016\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.mwm.net\/en\/gas-engines-gensets\/gas-engine-tcg-2016\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mwm.net\/en\/gas-engines-gensets\/gas-engine-tcg-2016\/#primaryimage\",\"url\":\"https:\/\/www.mwm.net\/wp-content\/uploads\/2021\/05\/TCG-2016.png\",\"contentUrl\":\"https:\/\/www.mwm.net\/wp-content\/uploads\/2021\/05\/TCG-2016.png\",\"width\":630,\"height\":551,\"caption\":\"V08\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.mwm.net\/en\/gas-engines-gensets\/gas-engine-tcg-2016\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.mwm.net\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Gas Engines \/ Generator Sets\",\"item\":\"https:\/\/www.mwm.net\/en\/gas-engines-gensets\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Gas Engine TCG 2016\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.mwm.net\/en\/#website\",\"url\":\"https:\/\/www.mwm.net\/en\/\",\"name\":\"MWM\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/www.mwm.net\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.mwm.net\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.mwm.net\/en\/#organization\",\"name\":\"Caterpillar Energy Solutions GmbH\",\"url\":\"https:\/\/www.mwm.net\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.mwm.net\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.mwm.net\/wp-content\/uploads\/2022\/02\/logo2.jpg\",\"contentUrl\":\"https:\/\/www.mwm.net\/wp-content\/uploads\/2022\/02\/logo2.jpg\",\"width\":260,\"height\":142,\"caption\":\"Caterpillar Energy Solutions GmbH\"},\"image\":{\"@id\":\"https:\/\/www.mwm.net\/en\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Gas Engine TCG 2016","description":"Suitable for all gas types. Mainly used for biogas plants and small CHP plants.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.mwm.net\/en\/gas-engines-gensets\/gas-engine-tcg-2016\/","og_locale":"en_US","og_type":"article","og_title":"Gas Engine TCG 2016","og_description":"Suitable for all gas types. Mainly used for biogas plants and small CHP plants.","og_url":"https:\/\/www.mwm.net\/en\/gas-engines-gensets\/gas-engine-tcg-2016\/","og_site_name":"MWM","article_modified_time":"2021-06-14T10:50:35+00:00","og_image":[{"width":630,"height":551,"url":"https:\/\/www.mwm.net\/wp-content\/uploads\/2021\/05\/TCG-2016.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.mwm.net\/en\/gas-engines-gensets\/gas-engine-tcg-2016\/","url":"https:\/\/www.mwm.net\/en\/gas-engines-gensets\/gas-engine-tcg-2016\/","name":"Gas Engine TCG 2016","isPartOf":{"@id":"https:\/\/www.mwm.net\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.mwm.net\/en\/gas-engines-gensets\/gas-engine-tcg-2016\/#primaryimage"},"image":{"@id":"https:\/\/www.mwm.net\/en\/gas-engines-gensets\/gas-engine-tcg-2016\/#primaryimage"},"thumbnailUrl":"https:\/\/www.mwm.net\/wp-content\/uploads\/2021\/05\/TCG-2016.png","datePublished":"2021-06-03T13:58:41+00:00","dateModified":"2021-06-14T10:50:35+00:00","description":"Suitable for all gas types. Mainly used for biogas plants and small CHP plants.","breadcrumb":{"@id":"https:\/\/www.mwm.net\/en\/gas-engines-gensets\/gas-engine-tcg-2016\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.mwm.net\/en\/gas-engines-gensets\/gas-engine-tcg-2016\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mwm.net\/en\/gas-engines-gensets\/gas-engine-tcg-2016\/#primaryimage","url":"https:\/\/www.mwm.net\/wp-content\/uploads\/2021\/05\/TCG-2016.png","contentUrl":"https:\/\/www.mwm.net\/wp-content\/uploads\/2021\/05\/TCG-2016.png","width":630,"height":551,"caption":"V08"},{"@type":"BreadcrumbList","@id":"https:\/\/www.mwm.net\/en\/gas-engines-gensets\/gas-engine-tcg-2016\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.mwm.net\/en\/"},{"@type":"ListItem","position":2,"name":"Gas Engines \/ Generator Sets","item":"https:\/\/www.mwm.net\/en\/gas-engines-gensets\/"},{"@type":"ListItem","position":3,"name":"Gas Engine TCG 2016"}]},{"@type":"WebSite","@id":"https:\/\/www.mwm.net\/en\/#website","url":"https:\/\/www.mwm.net\/en\/","name":"MWM","description":"","publisher":{"@id":"https:\/\/www.mwm.net\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.mwm.net\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.mwm.net\/en\/#organization","name":"Caterpillar Energy Solutions GmbH","url":"https:\/\/www.mwm.net\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mwm.net\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.mwm.net\/wp-content\/uploads\/2022\/02\/logo2.jpg","contentUrl":"https:\/\/www.mwm.net\/wp-content\/uploads\/2022\/02\/logo2.jpg","width":260,"height":142,"caption":"Caterpillar Energy Solutions GmbH"},"image":{"@id":"https:\/\/www.mwm.net\/en\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.mwm.net\/en\/wp-json\/wp\/v2\/pages\/85503","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mwm.net\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.mwm.net\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.mwm.net\/en\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mwm.net\/en\/wp-json\/wp\/v2\/comments?post=85503"}],"version-history":[{"count":4,"href":"https:\/\/www.mwm.net\/en\/wp-json\/wp\/v2\/pages\/85503\/revisions"}],"predecessor-version":[{"id":88601,"href":"https:\/\/www.mwm.net\/en\/wp-json\/wp\/v2\/pages\/85503\/revisions\/88601"}],"up":[{"embeddable":true,"href":"https:\/\/www.mwm.net\/en\/wp-json\/wp\/v2\/pages\/1062"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.mwm.net\/en\/wp-json\/wp\/v2\/media\/85505"}],"wp:attachment":[{"href":"https:\/\/www.mwm.net\/en\/wp-json\/wp\/v2\/media?parent=85503"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.mwm.net\/en\/wp-json\/wp\/v2\/tags?post=85503"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}