Performance Data - TCG 2032

Natural gas applications, NOx ≤ 500 mg/Nm3 *

TCG 2032 V12
R = Optimized for high total efficiency
Engine type 50 Hz 60 Hz**
Electrical output kW 3333 3000
Mean effective pressure bar 20.0 20.1
Thermal output ± 8% kW 2862 2539
Electrical efficiency % 43.9 43.9
Thermal efficiency % 42.6 42.1
Total efficiency % 86.5 86.0
Power to heat ratio*** 1.03 1.04
TCG 2032 V16R = Optimized for high total efficiency TCG 2032B V16R = Optimized for high total efficiency
Engine type 50 Hz 60 Hz** 50 Hz 60 Hz**
Electrical output kW 4300 4000 4500 4050
Mean effective pressure bar 19.4 20.2 20.3 20.4
Thermal output ± 8% kW 3698 3411 3668 3252
Electrical efficiency % 44.1 43.8 44.6 44.3
Thermal efficiency % 42.7 42.4 43.1 42.6
Total efficiency % 86.8 86.2 87.7 86.9
Power to heat ratio*** 1.03 1.03 1.03 1.04

* 5% O2 and dry exhaust gases

** On request

*** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.

Biogas, landfill gas, and sewage gas applications, NOx ≤ 500 mg/Nm3 *

TCG 2032 V16
X = Optimized for operation with biogases
Engine type 50 Hz 60 Hz**
Electrical output kW 3770 3510
Mean effective pressure bar 17.0 17.0
Thermal output ± 8% kW 3196 2880
Electrical efficiency % 43.0 43.3
Thermal efficiency % 41.9 40.6
Total efficiency % 84.9 83.9
Power to heat ratio*** 1.03 1.07

* 5% O2 and dry exhaust gases

** On request

*** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.

MWM Premium Antifreeze -20

High-performance coolant for MWM diesel and gas engines

MWM gas engine Premium oil

Test MWM Premium oil for gas engines

Spare parts

Click here to order spare parts for MWM gas engines and gensets.

CHP ROI Calculator

Calculate the profitability of MWM cogeneration power plants and gas engines.

Gas engines & Products

Gas Engine TCG 3020 V20

2,300 kWel

The Multi-Purpose Talent. Smart, secure plant control. Higher output and profitability despite compact design.

Gas engine TCG 3016

400 - 1,000 kWel

New development – greatly reduced operating and installation costs and fully digitized power plant control.

Modular Power Plant

Perfect modularity for a faster start of operations. Various customized solutions for the TCG 2032 gas engine.

Contact Sales

MWM Sales
Caterpillar Energy Solutions GmbH
Carl-Benz-Strasse 1
68167 Mannheim
Germany

Please fill out our contact form and we will call you back!