Skip to content
  • Contact Sales - Click here
  • search icon
  • About MWM
    • Jobs & Career
    • MWM Brand Strategy
    • MWM Sales Solutions
    • MWM Mission
    • MWM History
    • 100 Years of MWM Brand
  • Imprint
  • Privacy
  • Shop
  • DE
  • ES
  • ZH-HANS
MWM
  • About MWM
    • Jobs & Career
    • MWM Brand Strategy
    • MWM Sales Solutions
    • MWM Mission
    • MWM History
    • 100 Years of MWM Brand
  • News
    • News & Press Releases
    • Pictures & Graphics
    • Videos
    • Media Contact
    • Media Mailing List
  • Events
    • MWM Energy Days 2025
  • International Cases
  • Contact
    • Contact Form
    • Contact Sales
  • Global Locations
  • Downloads
  • Videos
  • Trainings
    • Learning Center Service
    • Training Center Sales
Contact Sales
Products & Services
  • Gas Engines / Generator Sets
    • Gas Engine TCG 3016

      New development – greatly reduced operating and installation costs and fully digitized power plant control.

    • Gas Engine TCG 3020

      The All-Round Talent. Smart, secure plant control. Higher output and profitability despite compact design.

    • Gas engine TCG 2032

      High reliability. Low operating costs. Gas types: natural gas, landfill gas, sewage gas, mine gas, coke oven gas. Mainly used in large IPP projects with up to 100 MWel.

    • Gas Engine TCG 2020

      Best electrical and thermal efficiency in its class. All gas types: natural gas, biogas, mine gas, landfill gas, sewage gas.

  • Distributed Power Plants
    • Cogeneration Power Plant Solutions

      Eco-friendly MWM cogeneration power plants with combined heat and power enable decentralized, economical and energy-efficient power production.

    • Container Cogeneration Plant

      Available for TCG 3016, TCG 3020 and TCG 2020 gas engines.

    • System Solutions

      MWM offers customized system solutions in order to meet diverse customer requirements in the best way possible.

    • Plant Engineering

      MWM offers comprehensive plant concepts from gas processing to plant control to cold and heat extraction.

  • Gas Applications
    • Power Plant Solutions for Public Utilities

      Public Utilities

      Flexibly manage base or peak loads with natural gas-fueled cogeneration power plants.

    • CHP Solutions for Industrial or Commercial Facilities

      Industrial or Commercial Facilities

      Reduced operating costs due to a highly efficient CHP, distributed generation or emergency standby power.

    • CHP Solutions for Greenhouses

      Greenhouses

      Highly-efficient CHP plants: Energy efficiency in plant nurseries.

    • Power Plant Solutions for Agricultural Biogas Plants

      Agricultural Biogas

      A highly efficient and profitable alternative for power generation.

    • Distributed Energy Solutions for Landfills

      Landfills

      Use of methane for sustainable power production in distributed power plants.

    • Cogeneration Solutions for Sewage Plants

      Sewage Plants

      Utilizing methane from wastewater treatment plants for electrical power production.

    • Distributed Gas Power Plants for Mines

      Mining

      Maximization of fuel resources.

    • References

      References

      Around the globe, MWM plants generate ecological and economic decentralized energy.

  • Services
    • Customer Service

      Customer Service

      The MWM Online Portal ensures direct support and quick diagnosis around the clock.

    • X-Change

      X-Change

      The X-Change part replacement program is an economically attractive alternative to on-site maintenance.

    • Maintenance and Repair

      Maintenance & Repair

      MWM service is characterized by long-term, trusting cooperation for the purpose of fulfilling individual customer needs and ensuring the economic success of the plant.

    • MWM Remote Asset Monitoring (RAM)

      MWM Remote Asset Monitoring (RAM)

      Everything under control: More transparency and value for CHP plants with MWM Remote Asset Monitoring.

    • MWM Retrofit Kits for Hydrogen Operation

      MWM Retrofit Kits for Hydrogen Operation

      Existing plants of the TCG 3016, 3020, and 2032 series can be upgraded with the MWM 25H2-Kit for operation with a hydrogen admixture of up to 25 vol%.

    • MWM SCR Catalyst Retrofitting

      MWM SCR Catalyst Retrofitting

      MWM SCR catalyst retrofit kit for gas engines: Meet all requirements of the 44th Federal Immission Control Ordinance in Germany and ensure the efficiency of your plant!

    • MWM Original Spare Parts

      MWM Original Spare Parts

      Protect and maintain the performance of your gas engine with the original MWM spare parts to ensure the reliable operation of your system.

    • Parts & Logistics

      Logistics

      With its logistics center in Lorsch, Germany, MWM guarantees efficient and reliable global spare-part supply.

    • Other MWM Service Products

      Other MWM Service Products

      Here you can find other MWM service products for the maintenance of your gas engine and retrofitting of your CHP plant.

    • MWM Service Tutorials

      MWM Service Tutorials

      The MWM video format "Do it the smart way" features tutorials and instructions for the maintenance of gas engines.

    • Trainings

      Trainings

      At the Mannheim training center, experienced trainers provide comprehensive, application-oriented expertise in the use of gensets and plants.

    • Financing

      Financing

      MWM project financing maximizes the individual flexibility and benefits for the customer.

  • Gas Expertise
    • Prime Power

      MWM plants to cover the base load may be small biogas gensets in Germany as well as large power plants in Asia or Africa.

    • Cogeneration & Trigeneration

      Combined energy generation or the use of power and heat or cold enables energy savings of up to 60 percent.

    • Gas Solutions

      MWM gas engines efficiently convert various gas types to power, heat, and cold.

    • Research & Development

      Research & Development

      Higher efficiency through intensive research from the calculation to the inspection.

    • Operations

      Operations

      The production processes of MWM are characterized by high manufacturing quality and optimum benefits.

    • Quality

      Quality

      MWM stands for premium quality in all areas of the value chain.

    • Sustainability

      Sustainability

      For MWM, sustainability means long-term efficiency along with modest use of resources.

    • MWM Hydrogen Power

      MWM Hydrogen Power

      MWM gas engines and hydrogen: The way to climate-friendly energy production.

    • MWM Cyber Security

      MWM Cyber Security

      Effectively protect your energy plant and your gas engine with MWM Cyber Security measures.

Mwm
  • About MWM
    • Jobs & Career
    • MWM Brand Strategy
    • MWM Sales Solutions
    • MWM Mission
    • MWM History
    • 100 Years of MWM Brand
  • News
    • News & Press Releases
    • Pictures & Graphics
    • Videos
    • Media Contact
    • Media Mailing List
  • Events
    • MWM Energy Days 2025
  • International Cases
  • Contact
    • Contact Form
    • Contact Sales
  • Global Locations
  • Downloads
  • Videos
  • Trainings
    • Learning Center Service
    • Training Center Sales
Home / MWM Newsflash / Newsflash 02 – January 2013 / Medium-Voltage Guideline

Medium-Voltage Guideline

Requirements for CHP plants per Medium-Voltage Guideline

Like photovoltaic and wind power plants, combined heat and power plants (CHPs) are used to generate electrical power. New legal requirements on feeding this electricity into the electrical power grid will take effect on January 1, 2013.

For decades, the Medium-Voltage Guideline specified that CHP systems needed to be taken off the grid immediately in the event of trouble. Special protective devices, such as vector jump relays, were developed and used to ensure quick disconnection. In power grid technology, CHP plants were considered to be “negative consumers,” which meant that they reduced the consumer load.

As a result of the ongoing decentralization of power generation systems, such as photovoltaic, wind and CHP, decentralized systems are becoming more and more important in the power generation industry. This is reflected by the requirements set forth in the guideline “Generating Plants Connected to the Medium-Voltage Network” (BDEW Technical Guideline, rev. June 2008, with a 4th version scheduled to take effect Jan. 1, 2013).

According to this Medium-Voltage Guideline, CHP systems must be part of the static and dynamic grid support system, just like wind, hydro and photovoltaic systems.

Static grid support has been required since January 1, 2010. Complete dynamic grid support must be provided beginning January 1, 2013. It is expected that certification will be required beginning January 1, 2014. In the event of certification bottlenecks, a transition period extending to December 31, 2014 will apply.
New requirements for gas engines and power generators

The technical requirements for static and dynamic grid support will shift requirements to the generation set (natural gas engine and generator) and to the plant operating mode. In the past, CHP plants were designed for maximum efficiency and power at cosϕ = 1.0. The revised version of the Medium-Voltage Guideline will add new requirements, such as extended voltage and frequency ranges, power reduction via frequency control, external power feed-in control, variable cosϕ and dynamic grid support. If a voltage dip above the specified curve occurs in dynamic grid support, the CHP must remain online and must be able to follow the voltage curve shown below in the event of an FRT event (fault ride-through).

Fig. 1: Specified voltage curve for FRT

The CHP plant may not disconnect from the grid until the voltage at the grid connection point is below the limit curve. For example, with a voltage dip below 30%, the disconnect may be immediate; with a voltage dip below 70%, it may occur after 150 msec.
Early tests ensure highest efficiency

Dynamic grid support places particularly high technical demands on the gensets. These units must be designed to comply with the FRT requirements, and compliance must be verified by a certifying organization. MWM already began initial tests on the new requirements applying to CHP plants in 2010 in order to obtain knowledge and experience on FRT behavior.

The tests were performed on an actual power grid. The voltage of the grid was reduced to the given test value by means of a test container, and the behavior of the genset was measured.

Measurements and the simulations show that the genset supports the grid voltage at a level of about 55% when voltage at the grid connection point dips to 30% for 150 msec. In this case the generator voltage is about 67% of the nominal value (Fig. 2). The generator current increases to 4.7 x In (nominal current) (Fig. 3). Figures 4 and 5 show the rpm variations and the angular displacement.

Fig 2: Voltage at the grid connection point and at the generator

 

Fig. 4: Genset rpm

 

Fig. 5: Angular displacement of the generator

Based on the measurements and the simulations, the MWM design series were tested in a timely manner, and the design was modified.

Therefore, beginning 2013 MWM gensets will comply with the new Medium-Voltage Guideline and make their contribution to grid stability. The required reactive power will also be provided.

The certification requirements were still pending as of our press date. The MWM gensets will be certified per TR8 over the medium term so that the certificates will be available by January 1, 2014.

Aside from the Medium-Voltage Guideline that applies to Germany, in other countries within and outside of the EU there are also country-specific specifications that apply to the conditions that must be met for parallel operation on the grid. More and more countries are revising these specifications in light of efforts to supply decentralized renewable energy.

In Europe, the European Network of Transmission System Operators for Electricity (ENTSO-E) has compiled corresponding specifications. The general requirements that must be met by country-specific guidelines/specifications are defined in the “Network Code for Requirements for Grid Connection Applicable to All Generators”. After this Network Code takes effect, it must be taken into account in country-specific guidelines.

Given that the specifications are currently being revised or issued for the first time in many countries, it will probably be necessary in some cases to individually document compliance with the specific requirements.

Links

  • Spare parts for MWM gas engines and gensets
  • TPEM – Digital Plant Control
  • Gas engine TCG 3016
  • Gas engine TCG 3020
  • Gas engine TCG 2020
  • Gas engine TCG 2032
  • Container Cogeneration Plant

Follow Us

  • MWM Shop
  • Facebook
  • LinkedIn
  • flickr
  • Issuu
  • Youtube
  • Wikipedia
  • MWM Energy Blog
  • MWM in East Europa/Central Asia
  • MWM in Latin America
Contact Us …
  • Imprint
  • Disclaimer
  • Privacy policy
  • Sitemap

© Caterpillar Energy Solutions GmbH, 2025