TCG 2020 V16 K
Gas Engine TCG 2020 V16 K
1,415 kWel
For the Asia-Pacific/Bangladesh region, the MWM TCG 2020 V16 K is available with 1,415 kWel.
- Electrical output of 1,415 kWel
- Specially adapted to Non-ISO Conditions
- Optimized for for Isolated Operation
MWM Gas Engine TCG 2020 V16 K
- For the Asia-Pacific/Bangladesh region, the MWM TCG 2020 V16 K is available with 1,415 kWel.
- TCG 2020 K was especially adapted to non-ISO conditions such as high altitudes or high intake air temperatures in the field of natural gas
On this page
Description – MWM Gas Engine TCG 2020 V16 K
Performance Data – MWM Gas Engine TCG 2020 V16 K
Specifications and Service Intervals – MWM Gas Engine TCG 2020 V16 K
Description – MWM Gas Engine TCG 2020 V16 K
TCG 2020 V16 K – Optimized for Isolated Operation and Non-ISO Conditions
- Load response in only seven steps
- Fast and reliable supply in the event of grid failures or in isolated operation
- Special variant available for high altitude setup and different intake air temperatures
K Editions: Maximum Output at Low Costs
- Improved output capacity of TCG 2020 K under non-ISO conditions and excellent load response through optimum turbocharger design with broad performance map
- For the Asia-Pacific/Bangladesh region, the MWM TCG 2020 V16 K with 1,415 kWel can optimally meet the high local requirements.
- New turbocharger TCR 16 for TCG 2020 with water-cooled bearing housing eliminates need for separate maintenance stages for the turbocharger
- Low turbocharger maintenance costs lead to lower life cycle costs for gas engines/electricity gensets.
Performance Data –
MWM Gas Engine TCG 2020 V16 K
Natural gas applications, NOx ≤ 500 mg/Nm3 *
TCG 2020 V16 K K = Optimized for robustness and low CAPEX | |||
---|---|---|---|
Engine type | 50 Hz | ||
Electrical output | kW | 1415 | |
Thermal output ± 8% | kW | 1590 | |
Electrical efficiency | % | 40.7 | |
Thermal efficiency | % | 45.7 | |
Total efficiency | % | 86.4 | |
Power to heat ratio ** | 0.89 |
* With 5% O2 and dry exhaust gas
** The power to heat ratio is calculated by dividing the electrical efficiency by the thermal efficiency. Please remember that this is a theoretical value that may deviate from actually measured values.
The values given in these tables are information purposes only and not binding. The information given in the offer is decisive. Other unit variants with other generators are available.
Specifications and Service Intervals –
MWM Gas Engine TCG 2020 V16 K
Dimensions and Weights
TCG 2020 V16 K K = Optimized for robustness and low CAPEX | |||
---|---|---|---|
Engine type | 50 Hz | ||
Length | mm | 5430 | |
Width | mm | 1810 | |
Height | mm | 2210 | |
Dry weight genset | kg | 13300 | |
Bore / stroke | mm | 170/195 | |
Displacement | dm3 | 70.8 | |
Speed | min-1 | 1500 | |
Mean piston speed | m/s | 9.8 |
The values given in these tables are information purposes only and not binding. The information given in the offer is decisive. Other unit variants with other generators are available.
Service Intervals
TCG 2020 V16 K | First service (check valve clearance) | Cylinder head inspection | Major overhaul |
---|---|---|---|
Natural gas, purified biogas, sewage gas, and landfill gas | 4000 oh | 32000 oh* | 64000 oh |
Unpurified biogas, sewage gas, and landfill gas | 2000 oh | 16000 oh* | 64000 oh |
* “at the latest”
The values given in these tables are information purposes only and not binding. The information given in the offer is decisive. Other unit variants with other generators are available.
MWM Premium Antifreeze -20
High-performance coolant for MWM diesel and gas engines.
MWM Gas Engine Premium Oil
Test MWM Premium oil for gas engines.
MWM Spare parts
With its logistics center in Lorsch, Germany, MWM guarantees efficient and reliable global spare-part supply.
MWM Remote Asset Monitoring
Everything under control: More transparency and value for CHP plants with MWM Remote Asset Monitoring (RAM).
Gas Engines & Products
Distributed Power Plants
MWM stands for highly-efficient and eco-friendly combined heat and power (CHP) plants for distributed power generation
Gas Engine TCG 3016
New development – greatly reduced operating and installation costs and fully digitized power plant control.
Gas Engine TCG 2032
High reliability. Low operating costs. Gas types: natural gas, landfill gas, sewage gas, mine gas, coke oven gas. Mainly used in large IPP projects with up to 100 MWel.
Container Cogeneration Plant
Compact modules for the TCG 3016, TCG 3020 and 2020 gas engines. Complete turnkey systems for special applications.